neap
Shortage record · ATC L01BC02

FluorouracileL01BC02 · also fluorouracilo

Active in 4 of 5 served registers8records
EUCZESFRIT

6 short now, 2 announced. Data version 9 Nov 2026.

On 9 November 2026, fluorouracile (ATC L01BC02) had 8 active shortage records in 4 of the 5 EU registers Neap serves: Italy 3, Spain 2, France 2, Czechia 1.

As the registers print it: fluorouracilo (Spain); fluorouracile (France); fluorouracile (Italy). Czechia lists product names only.

Country by country

Active records under L01BC02, as each register defines a record: packs in Czechia and Spain, products elsewhere.

EUEMA
No active record under L01BC02 in this registerNo record does not mean available
0
The register says preruseni1 announced
1
SpainAEMPS CIMA
The register says tipoProblemaSuministro 10, activo true and tipoProblemaSuministro 7, activo true2 short now
2
FranceANSM
The register says Rupture de stock and Tension d'approvisionnement2 short now · 2 with no expected end · ATC matched by substance name on 2
2
ItalyAIFA
The register says Lista dei farmaci temporaneamente carenti2 short now · 1 announced · 1 with no expected end · 2 past the expected end
3
Germany, Hungary, Slovenia
Held back until each regulator confirms reuse terms in writing
Held back
Finland, Ireland
Terms forbid commercial use, or robots.txt disallows the path
Out

The records

Each code opens the live lookup for that pack.

CountryCodeProduct and packStatusRegister saysStartExpected end
CZ0267308TOLAK40MG/G CRM 20GAnnouncedpreruseniKapacitní/distribuční důvody4 Jan 202731 Mar 2027
ES667193FLUOROURACILO ACCORD 50 mg/ml SOLUCION INYECTABLE O PARA PERFUSION EFG, 1 vial de 5 mlShortagetipoProblemaSuministro 10, activo true1 Oct 202631 Dec 2026
ES603544FLUOROURACILO ACCORD 50 mg/ml SOLUCION INYECTABLE O PARA PERFUSION EFG, 1 vial de 100 mlShortagetipoProblemaSuministro 7, activo true8 Jul 202631 Dec 2026
FR1543Fluorouracile Pfizer 50 mg/ml, solution à diluer pour perfusion - flacon de 100 mlShortageRupture de stockNot statedNot stated
FR969Fluorouracile Accord 50 mg/ml, solution à diluer pour perfusion, flacon de 100 mlSupply tensionTension d'approvisionnementNot statedNot stated
IT040593042FLUOROURACILE AHCL50 MG/ML SOLUZIONE INIETTABILE O INFUSIONE 1 FLACONCINO IN VETRO DA 100 MLAnnouncedLista dei farmaci temporaneamente carentiProblemi produttivi27 Nov 2026Not stated
IT044062038FLUOROURACILE HIKMA50 MG/ML SOLUZIONE INIETTABILE/PER INFUSIONE 1 FLACONCINO IN VETRO DA 20 MLShortageLista dei farmaci temporaneamente carentiProblemi produttivi5 Aug 202615 Sep 2026
IT044062040FLUOROURACILE HIKMA50 MG/ML SOLUZIONE INIETTABILE/PER INFUSIONE 1 FLACONCINO IN VETRO DA 100 MLShortageLista dei farmaci temporaneamente carentiElevata richiesta/problemi produttivi9 May 20231 Oct 2026

Is it new, or recurring?

Czech products under L01BC02 with an open interruption notice, by month, from SUKL's dated notices. 51 interruption intervals on record since Jun 2011.

0123Dec 2023: 0 products with an open interruptionJan 2024: 0 products with an open interruptionFeb 2024: 1 product with an open interruptionMar 2024: 3 products with an open interruptionApr 2024: 2 products with an open interruptionMay 2024: 3 products with an open interruptionJun 2024: 3 products with an open interruptionJul 2024: 3 products with an open interruptionAug 2024: 3 products with an open interruptionSep 2024: 2 products with an open interruptionOct 2024: 1 product with an open interruptionNov 2024: 1 product with an open interruptionDec 2024: 1 product with an open interruptionJan 2025: 0 products with an open interruptionFeb 2025: 0 products with an open interruptionMar 2025: 0 products with an open interruptionApr 2025: 0 products with an open interruptionMay 2025: 0 products with an open interruptionJun 2025: 0 products with an open interruptionJul 2025: 0 products with an open interruptionAug 2025: 0 products with an open interruptionSep 2025: 0 products with an open interruptionOct 2025: 0 products with an open interruptionNov 2025: 0 products with an open interruptionDec 2025: 0 products with an open interruptionJan 2026: 1 product with an open interruptionFeb 2026: 0 products with an open interruptionMar 2026: 1 product with an open interruptionApr 2026: 0 products with an open interruptionMay 2026: 0 products with an open interruptionJun 2026: 0 products with an open interruptionJul 2026: 0 products with an open interruptionAug 2026: 0 products with an open interruptionSep 2026: 0 products with an open interruptionOct 2026: 0 products with an open interruptionNov 2026: 0 products with an open interruptionDec 2023Jan 2024Jan 2025Jan 2026

Spain, France, Italy and the EMA publish the present only, so their history is Neap's own daily snapshots, starting 7 Nov 2026: Spain 2 on 9 Nov 2026, EU 0 on 9 Nov 2026, France 2 on 9 Nov 2026, Italy 2 on 9 Nov 2026.

Embed this status

Fluorouracile: active in 4 of 5 EU shortage registers on 9 Nov 2026

Rebuilt with each data version. Keep the link: it carries the sources.

Beside it in the code

Credit lines

Source: SUKL (Statni ustav pro kontrolu leciv). SUKL does not endorse this service or this use of its data. Terms of use: https://opendata.sukl.gov.cz/podminky-uziti-otevrenych-dat Source: AEMPS, CIMA (cima.aemps.es). CIMA publishes no last-update date for its supply problem list, so the date Neap retrieved it is given instead. Source: ANSM (ansm.sante.fr). Date of last update is stated per record. Facts reproduced without alteration of meaning. Source: AIFA (Agenzia Italiana del Farmaco), licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Data: https://www.aifa.gov.it/documents/20142/847339/elenco_medicinali_carenti.csv. Fields normalised by Neap.

Automated and unreviewed. Neap reads official sources automatically and no person checks each answer. Data can be incomplete, late or wrong. Always verify against the official source linked with every answer before you act. Not legal, tax or customs advice. Not medical advice. Ask a pharmacist or doctor. A supply status is not a clinical recommendation. Records join at ATC level only: strength, form and pack are not normalised, so one code can cover products that are not interchangeable. ATC codes are shown as each register publishes them. The ATC classification is maintained by the WHO Collaborating Centre for Drug Statistics Methodology, which does not endorse Neap.